RC2000 Service Manual Chapter 5 Upgrading the RC2000 32
Research Concepts, Inc; 10679 Widmer; Lenexa, Kansas; USA 66215 WWW.RESEARCHCONCEPTS.COM
7. Go to LIMITS mode. WITHOUT MOVING THE ANTENNA set the down and east limits. AFTER
THE EAST AND DOWN LIMITS HAVE BEEN SET, jog the antenna to the positions for the west and
up limit recorded in step 1. Set the west and up limits. After the west and up limits have been set,
exit LIMITS mode by hitting the MODE KEY.
8. Go to CONFIG mode and key in the data recorded in step 2 above. Each entry must be terminated
with the ENTER KEY. After the data has been entered scroll through the CONFIG mode items
(using the SCROLL UP and SCROLL DOWN keys) and make sure that the data has been entered
correctly.
9. In this step, the positions of the geostationary satellites are stored in non-volatile memory. Go to
SETUP mode. Position the antenna on each of the satellites which were recorded in step 3 above.
Select the satellite name, enter the satellite longitude, and move the polarotor to the recorded H and
V positions in response to the appropriate SETUP mode prompts.